Welcome~Shanghai Leading Water Treatment Equipment Co.,Ltd

LAB-Exrtact-V

DI pure water: Conductivity <0.1 μS/cm
Ultrapure water:
resistivity 18.25MΩ.cm@25°C,
TOC: <3 ppb,
particles (>0.22 um) <1/ml,
microorganism <1 cfu/ml,
pyrogen<0.001EU/ml,
RNases≤0.01ng/ml,
DNases≤3Pg/ul


Product Features

Ø Colored touched screen, humanized operation interface make users completely monitor controllers working status and real-time data.

Ø Inbuilt feed water pressure test gauge to real time monitor tap water pressure and filters blocking.

Ø Lifetime of PP cotton, activated carbon filter, RO membrane and ultra purification columns can be set to display the elapsed&rest time of consumables. Automatic reminder for filter replacement to avoid water quality decreasing.

Ø Feed water, RO and UP water three ways water quality sensor and five ways switches signal are accessed integrated, with functions of timing quantitative water taking.

Ø Equipped with USB Host interface, it supports data export function of historical alarm record and historical water intake record.

Ø Low-voltage 24VDC is used as the main power supply, which meets the safety regulations and meets the requirements of humid environment, and will not cause personal injury.

Ø Can be with inner circulation system to ensure water quality keep at the highest level. ( optional)


Application

Atomic absorption/emission spectroscopy, mass spectrum, TOC detection, environmental monitoring, biochip development, trace organic matter analysis


Product parameter

Inlet water source

RO water or purified water

Water flow speed

1-1.5 L/min

Machine capacity

60-90 L/H

Output

Water quality

DI water: Conductivity <0.1 μS/cm (ASTM type II water)

UP water: resistivity 18.25MΩ.cm@25°C (ASTM type I water)

TOC: <3 ppb, particles (>0.22 um) <1/ml, microorganism <1 cfu/ml

Process

image.png

Filter function

AC: Granular activated carbon filter: remove color, odor, residual chlorine and heavy metals

UV: UV germicidal lamp: sterilization device, decomposition and photo oxidation OC, lower TOC

UP: Ultra-purification column: ion exchange resin bed, H+ and OH- ion removal

TF: 0.2μm terminal filter, final removal for < 0.2μm bacteria


Operation screen display

image.pngimage.pngimage.pngimage.png

Product consumables list

No

Filter element

Replace cycle

Quantity

Remark

1

11" activated carbon filter

About 4-6 months

1 pc


2

11’’ deionization column

About 1000L/ pc

2 pcs

3

11" ultra-purification column (imported resin)

About 1000L/ pc

4 pcs

4

Dual wavelength UV lamp (import)

About 9000 hours

1 pc

5

0.2 μm imported PES terminal filter

About 2-3 years

1 pc


PREVIOUS:LAB-R-VF-15 NEXT:LAB-WP-VF-15

INQUIRY

Top